You have added this product to your favorite list.
You have removed this product from your favourite list.
This company has been added successfully. Check My Favourite.
This company has been removed from your favourite list.
This company has been added to your inquiry cart.
This company has been removed from your inquiry cart.
This product has been added to your inquiry cart.
This product has been removed from your inquiry cart.
Maximum number of Product/Company has been reached in inquiry cart.
Login to NEWPAGES
Stay signed in
Daily Login Reward

Congratulations! You’ve earned your daily login reward for today!

5 NP PointHere are the reward you’ve earned!
Check your Daily Login Rewards

Be sure to come back everyday for more rewards!
Thanks!

Back
Seni Jaya Logo
VG Instruments (SEA) Sdn Bhd
VG Instruments (SEA) Sdn Bhd (903421-U)
Visitor

Cone Differential Pressure Meter (ACONE)

16-Dec-2022
Cone Differential Pressure Meter (ACONE)
Product Viewed 170
Product Specifications
Styles Acone flow element used with either ALDPT or ALDPTMV
Sizes ~10" (15-250 mm)
Measuring range Based on Re > 8000 For gases, liquids and steam
Process Temperature 320~1500°F (-196~850 °C)
Accuracy Liquid: ± 0.5% of reading Gas & Steam: ± 1.0% of reading
Metering tube SS #304L/SS #316L, CPVC ,PTFE, Brass, A106B A335-P11, A335-P22, Dual - Phase Steel, Inconel 625, Hastelloy C276
Outputs & Electronics 4~20 mA square root output, HART, MODBUS
Connection NPT, flanged (JIS, ANSI and DIN), wafer or butt weld
Process Medium Where space is limited; reduced straight pipe requirements of 0-3 D upstream and 0-1 D downstream
Application Any application where the flow engineer prefer DP flow meters; extreme high temp applications

SmartMeasurement’s ACONE differential pressure flowmeter is designed for the harshest operating environments and the widest variety of fluids. This sensor consistently outperforms traditional ΔP devices and other major flow technologies. The ACONE’s enhanced performance is due to the shape and position of a fixed-cone inside of the flow body in relation to the ΔP measurement ports. The cone interacts with the flow, reshaping the fluid’s velocity profile and creating a region of lower pressure immediately downstream of itself. Two pressure taps are designed to measure the differential pressure between the static line pressure and the low-pressure zone created downstream of the cone. Flow is calculated by the Bernoulli equation of conservation of energy. The cone shape also acts as its own flow conditioner, fully conditioning any turbulence inflow due to limited upstream and downstream straight runs.

The ACONE is a primary element – it may be used in conjunction with third-party differential pressure transducers or with pressure transmitters supplied by SmartMeasurement. It is available in sizes ranging from ½” to 120” with a number of available options for process connections and materials of construction. The ACONE’s high performance, combined with its wide array of available features and relatively low cost make it a superior value versus other differential-pressure based flow measuring technologies.
 

Process Connections: NPT, Flange, Wafer or Butt weld
Sizes: ½” ~ 120″ (15~300mm)
Measuring Range: Based on Re > 8000 for liquid, gas, & steam
Temperature: -320~1500°F (-168~850°C)
Pressure: up to 61,000 psig (420 Mpa)
Accuracy: Liquid ± 0.5% of reading; Gas & Steam ± 1.0% of reading Gas & Steam: ± 1.0% of reading
Turndown Ratio: Better than 10:1
Repeatability: ± 0.1% of reading
Flange Types: JIS 10K / JIS 20K / JIS 40K, ANSI 150# to ANSI 2500#, DIN PIN 10 to PN 40ANSI 150# to ANSI 2500#DIN PIN 10 to PN 40
Piping Requirments: 0-3Ф upstream and 0-1Ф downstream
Standard Beta Ratios: 0.45 through 0.85, special betas available
Weight: Wafer: 22~28 lbs (10 ~ 13 kg) to 12″ (DN300)Insertion: 33 lbs (15 Kg)
Signal Interface: RS232 & RS485, HART
Display Units: m³/h (standard)
Power Supply: 110/220 VAC or isolated 14~36 VDC
Data storage: EPROM storage up to 5 years
Process Connections: NPT, Flange, Wafer or Butt weld
Sizes: ½” ~ 120″ (15~300mm)
Measuring Range: Based on Re > 8000 for liquid, gas, & steam
Temperature: -320~1500°F (-168~850°C)
Pressure: up to 61,000 psig (420 Mpa)
Accuracy: Liquid ± 0.5% of reading; Gas & Steam ± 1.0% of reading Gas & Steam: ± 1.0% of reading
Turndown Ratio: Better than 10:1
Repeatability: ± 0.1% of reading
Flange Types: JIS 10K / JIS 20K / JIS 40K, ANSI 150# to ANSI 2500#, DIN PIN 10 to PN 40ANSI 150# to ANSI 2500#DIN PIN 10 to PN 40
Piping Requirments: 0-3Ф upstream and 0-1Ф downstream
Standard Beta Ratios: 0.45 through 0.85, special betas available
Weight: Wafer: 22~28 lbs (10 ~ 13 kg) to 12″ (DN300)Insertion: 33 lbs (15 Kg)
Signal Interface: RS232 & RS485, HART
Display Units: m³/h (standard)
Power Supply: 110/220 VAC or isolated 14~36 VDC
Data storage: EPROM storage up to 5 years


Refer to the link for more details: https://www.smartmeasurement.com/cone-differential-pressure-meter/

Send your message to VG Instruments (SEA) Sdn Bhd

Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.

Get the latest VG Instruments (SEA) Sdn Bhd App for Android
Send us your inquiry or question
Main Office

VG Instruments (SEA) Sdn Bhd (903421-U)
12A, Jalan Dagang SD2/1G, Bandar Sri Damansara, Kepong, 52200 Kuala Lumpur, Malaysia.
Google Maps Waze

Tel: +603-6276 8363
Fax: +603-6276 9363

Email: sales@vginstruments.com, loosw@vginstruments.com
Website: https://www.vginstruments.com.my
Website: https://vginstruments.newpages.com.my/
Website: http://vginstruments.n.my/

Social Media Link
  • facebook

Powered by NEWPAGES