WeatherMaker® Standard-Efficiency Single-Packaged Rooftop Units 50TCQ Heat Pump Units with Puron® (R-410A) Refrigerant 6 to 20 Nominal Tons

28-Mar-2020
WeatherMaker® Standard-Efficiency Single-Packaged Rooftop Units 50TCQ Heat Pump Units with Puron® (R-410A) Refrigerant 6 to 20 Nominal Tons
产品已浏览 327

Heat Pump Units with Puron® (R-410A) Refrigerant

6 to 20 Nominal Tons

WeatherMaker® 50TCQ rooftop units were designed to be easy to install, maintain, and operate, with customer-requested features including a gage port, centralized control center, plug-and-play accessory board, ''no-strip screw'' collars, and hinged access panels. Units are field-convertible to horizontal airflow without special adapter curbs or kits, making it easy for the installer to adjust to unexpected jobsite complications. Units are pre-wired and pre-charged with environmentally sound Puron (R-410A) refrigerant and are factory tested.


carrier-AHRI-340-360-Unitary-Large-AC
carrier-c-ul-us
carrier-intertek-ETL-listed-C-US
carrier-energy-star

Performance Features

 

  • ASHRAE 90.1 compliant
  • Single-stage capacity control (sizes 04 to 07)
  • Two-stage cooling capacity control (sizes 08 to 24)
  • Up to 13.4 SEER, 12.2 IEER, 11.2 EER, HSPF 7.7, and COP 3.4
  • Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit
  • Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Maintenance Features

 

  • Control terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Belt drive evaporator-fan motor and pulley combinations available to meet any application
  • Electric drive X13 (5 speed/torque) motor (sizes 04 to 06)
  • Two-inch disposable return air filters

Installation Features

 

  • Same footprint as installed Carrier 3-12.5 ton rooftops back to 1989, reducing installation costs and time
  • Field convertible from vertical to horizontal airflow for slab mounting (sizes 04-14)
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point electric and controls connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots
  • Dedicated vertical and horizontal airflow models available (sizes 17 to 28 only)

Reliability Features

 

  • Scroll compressors with internal line-break overload protection
  • Compressor crankcase heaters (sizes 05 to 24)
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Loss of charge, freeze protection, and high-pressure switches
  • Dependable time/temperature defrost board and logic


Factory-Installed Options

 

  • Cabinet
    • Thru-the-base electrical or gas-line connections
    • Hinged access panels
  • Coil Options
    • Cu/Cu indoor and/or outdoor coils
    • Pre-coated outdoor coils
    • Premium, E-coated outdoor coils
  • Condenser Protection
    • Condenser coil hail guard (louvered design)
  • Controls
    • PremierLink DDC communicating controller
    • RTU OPEN multi-protocol controller
    • Smoke detector (supply and/or return air)
  • Economizers & Outdoor Air Dampers
    • EconoMi$er IV (for electro-mechanical controlled RTUs)
    • EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD)
    • EconoMi$er2 (for DDC controlled RTUs)
    • Ultra-low leak economizer dampers
    • Motorized 2 position outdoor-air damper
    • Manual outdoor-air damper (sizes 17-24)
    • Barometric relief
    • Power exhaust (sizes 17-24)
  • Economizer Sensors & IAQ Devices
    • Single dry bulb temperature sensors
    • Single enthalpy sensors
    • CO2 sensor (wall, duct, or unit mounted)
  • Indoor Motor & Drive
    • Multiple motor and drive packages
    • Staged Air Volume (SAV) Indoor Fan Speed System (sizes 08-30)
  • Power Options
    • Convenience outlet (powered)
    • Convenience outlet (unpowered)
    • Non-fused disconnect

Field-Installed Accessories

 

  • Cabinet
    • Thru-the-base electrical or gas-line connections
  • Condenser Protection
    • Condenser coil hail guard (louvered design)
  • Controls
    • Thermostats, temperature sensors, and subbases
    • PremierLink DDC communicating controller
    • RTU OPEN multi-protocol controller
    • Smoke detector (supply and/or return air) (sizes 17-24)
    • Time Guard II compressor delay control circuit
    • Filter status switch
    • Fan status switch
  • Economizers & Outdoor Air Dampers
    • EconoMi$er IV (for electro-mechanical controlled RTUs)
    • EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD)
    • EconoMi$er2 (for DDC controlled RTUs)
    • Ultra-low leak economizer dampers
    • Motorized 2 position outdoor-air damper
    • Manual outdoor-air damper
    • Barometric relief
    • Power exhaust
  • Economizer Sensors & IAQ Devices
    • Single dry bulb temperature sensors
    • Differential dry bulb temperature sensors
    • Single enthalpy sensors
    • Differential enthalpy sensors
    • CO2 sensor (wall, duct, or unit mounted)
  • Electric Heat
    • Multiple Electric Resistance Heater KW Sizes
    • Single Point kit
  • Low Ambient Control
    • Winter start kit
    • Motormaster head pressure controller
  • Roof Curbs
    • Roof curb 14'' (356mm)
    • Roof curb 24'' (610mm)
Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) EER Dimensions (in) LxWxH At 47°F At 17°F Unit Weight (lbs)
Heating Capacity (Btuh) (HSPF) COP Heating Capacity (Btuh) (HSPF) COP
6 1 11.1 74 x 47 x 41 67000 3.30 34800 2.25 630
7.5 2 11.2 88 x 59 x 49 86600 3.40 48000 2.25 885
8.5 2 11.2 88 x 59 x 49 96000 3.30 54500 2.25 910
10 2 11.0 88 x 59 x 49 116000 3.40 62300 2.25 1050
12.5 2 10.6 116 x 63 x 57 142000 3.20 76000 2.05 1370
15 2 10.8 128 x 87 x 49 166000 3.30 103000 2.40 1775
20 2 10.5 141 x 87 x 49 220000 3.30 134000 2.30 2100

发信息至 United Faith Sdn Bhd

谢谢您的询问!
我们的客服会尽快联络您。

如需咨询或问题,联系我们
总办事处

United Faith Sdn Bhd (1253020-D)
6 (Ground Floor), Jalan BPU 6, Bandar Puchong Utama, 47100 Puchong, Selangor, Malaysia.
Google Maps Waze

电话: +6012-2631315, +6012-5992610

邮件: service@aircond2u.my
网址: https://www.unitedfaith.com.my
网址: https://unitedfaith.newpages.com.my/
网址: http://unitedfaith.n.my/

其他办事处

SG Branch : United Faith Pte Ltd
7030, Ang Mo Kio Ave 5, #01-23, Northstar@AMK, Singapore 569880.
Google Maps Waze

电话: +65-9106 6813

KL Branch
8G, Jalan Pandan 2/3, Pandan Jaya, 55100 Kuala Lumpur, Malaysia.
Google Maps Waze

电话: +6012-491 2610

PJ Branch
13, Jalan 21/37, SS 2, 47300 Petaling Jaya, Selangor, Malaysia.
Google Maps Waze

电话: +6012-599 2610

社交媒体链接
  • facebook

Powered by NEWPAGES