ULLTRA™ High Efficiency Transformers

12-Jun-2018
ULLTRA™ High Efficiency Transformers
标签:
-
产品已浏览 115

ULLTRA High Performance transformers are designed to deliver more energy savings than any other transformer on the market. The result is a high performing transformer that offers the highest efficiency in the industry under either linear or non-linear loading and maintains these high efficiency levels at not only 35% loading, but over the entire load range.

While other energy efficient transformers on the market may meet new, more demanding standards such as NEMA Premium and CSL3, these standards only restrict losses under linear loading and at 35% load levels. When it comes to higher load levels and non-linear loading, other transformers on the market can’t offer the same high efficiencies under these conditions. ULLTRA High Performance transformers actually exceed NEMA Premium efficiency levels at their peak performance loading of 50%, thereby assuring the most energy savings under any loading.

ULLTRA High Performance Transformers offer quicker payback periods, and are engineered to perform. All ULLTRA Transformers are real-world tested in Mirus’ Harmonics & Energy Lab.

Applications

A perfect solution for any application where energy efficiency and lower life cycle costs are critical – K-12 and Higher Education, Government, Healthcare, Broadcasting, Commercial, Industrial and LEED buildings. Applications that expect heavier loads such as Data Centers, Solar and other Alternative Energy projects, will benefit from the ULLTRA Series Transformers' ability to maximize savings under ANY load and for ANY load profile.

Models

ULLTRA™ - Ultra Low Loss Transformer
  • Optimized for any load level making ULLTRA the only transformer ideally suited for both light or heavy loading conditions
  • Linear load losses are a full 30% lower than the already low levels defined by NEMA TP-1
  • Efficiencies meet NEMA Premium levels at the mandated 35% loading and even exceed these levels at the transformer’s peak design loading of 50%
  • Harmonic losses are also reduced to ensure efficiencies meet NEMA TP-1 requirements even under ‘real world’ non-linear loading
  • Inrush currents (< 8x rated) and audible noise (3dB lower than standard) are extremely low
  • Ideal for Solar Power or other applications where transformer loading varies widely and electricity rates are high

ULLTRA-H1E™ - Harmonic Mitigating Transformer

In applications where non-linear loading is expected to be severe, the ULLTRA-H1E combines the proven harmonic mitigating properties of Mirus’ Harmony™ HMT line with superior energy efficiency, low inrush, and low audible noise found in the ULLTRA design.
  • Voltage distortion (flat-topping) is minimized by cancelling zero sequence fluxes within the secondary windings and eliminating circulating currents in the primary windings
  • Treats triplen harmonics (3rd and 9th) within the transformer and 5th and 7th upstream
  • The highest efficiency harmonic mitigating transformer from the company that first introduced HMT’s to the market in the early 1990’s

Features

  • Highest efficiencies in the industry at any load profile and at all load levels
  • Lowest 'Life Cycle Costs' for best paybacks and improved bottom line
  • Improves reliability by reducing voltage distortion
  • Exceeds CSL-3 and NEMA Premium requirements in a wider load range
  • Exceeds NEMA TP-1 efficiencies under non-linear loading
  • Energy savings are realized even during peak load conditions when environmental impact is greatest
  • Lower losses minimize energy waste and protect the environment by reducing greenhouse gas emissions
  • Contributes to LEED (Leadership in Energy Efficient Design) in Energy & Atmosphere and Innovation & Design categories
  • Performance validated through linear and non-linear load testing in Mirus’ Harmonics & Energy Lab
  • Inrush magnetization currents are the lowest in the industry
  • Lower audible noise levels: 3dB to 5dB below NEMA ST-20 requirements
发信息至 UTC Engineering Sdn Bhd

谢谢您的询问!
我们的客服会尽快联络您。

获取最新的 UTC Engineering Sdn Bhd 应用程序 iOSAndroid
如需咨询或问题,联系我们
总办事处

UTC Engineering Sdn Bhd (805959-D)
3 & 5, Jalan USJ 21/11, UEP Subang Jaya, 47630 Selangor, Malaysia.
Google Maps Waze

电话: +603-8023 6708
传真: +603-8023 6709

邮件: yewtc@ee.com.my
网址: http://www.utcesb.com.my
网址: https://utcesb.newpages.com.my/
网址: http://utcesb.n.my/

Powered by NEWPAGES