■Alarm setter with digital monitor display.
■Lineup of DC input and temperature sensor input products.
■Build-in 2 or 4 alarm function in one unit
Model Designation
① Measuring Input
DC Input
Model |
Measuring Range |
Input Resistance |
Over Load |
02 |
± 99.99 mV |
10 kΩ |
DC ±10 V |
03 |
± 999.9 mV |
100 kΩ |
DC ±100 V |
04 |
0 to 5 V |
500 kΩ |
DC ±250 V |
05 |
± 9.999 V |
1 MΩ |
DC ±250 V |
06 |
± 99.99 V |
1 MΩ |
DC ±250 V |
09 |
1 to 5 V |
1 MΩ |
DC ±250 V |
00 |
DC voltage input other than the above. (In between 100 mV and 100 V) |
22 |
± 99.99 μA |
1 kΩ |
DC ±20 mA |
23 |
± 999.9 μA |
100 Ω |
DC ±50 mA |
24 |
± 5.000 mA |
20 Ω |
DC ±100 mA |
25 |
± 9.999 mA |
10 Ω |
DC ±150 mA |
26 |
± 9.999 mA |
1 Ω |
DC ±500 mA |
27 |
± 9.999 mA |
0.1 Ω |
DC ±2 A |
29 |
4 to 20 mA |
12.5 Ω |
DC ±150 mA |
20 |
DC current input other than the above. (In between 100 μA and 100 mA) |
-
Accuracy:
-
± (0.1% of FS + 1 digit)
Defined at 23oC ± 5oC.
-
Temperature coefficient:
-
±150 ppm/oC, defined at the operating temperature range 0 to 50oC.
② Output Signal
Code |
Specifications |
1 |
Two relay contact output |
2 |
Four relay contact output |
3 |
Two open collector output |
4 |
Four open collector output |
③ Power Supply Voltage
Code |
Power Supply Voltage |
A |
AC 100 to 240 V |
B |
DC 12 to 24 V |
C |
DC 110 V |
① Measuring Input
Thermocouple thermometer
Code |
Temperature Sensor |
Measuring Range |
Display Range |
2 |
R |
100 to 1768°C |
-50 to 1800°C |
K |
-200 to 1372°C |
-270 to1400°C |
E |
-200 to 1000°C |
-270 to 1050°C |
J |
-200 to 1200°C |
-210 to 1250°C |
T |
-200 to 400°C |
-270 to 420°C |
B |
600 to 1800°C |
-20 to 1820°C |
N |
-200 to 1300°C |
-230 to 1350°C |
S |
0 to 1768°C |
-50 to 1800°C |
WRe5-26 |
0 to 2320°C |
-20 to 2350°C |
-
Accuracy:
-
±(0.1% of FS + 1 digit) Defined at 23oC±5oC, in the measuring range.
-
Cold junction compensation:
-
±1oC
Defined at the operating temperature range 0 to 50oC.
Calibration is with each referential thermoelectricity power of JIS C-1602-1995.
-
Temperature coefficient:
-
±150ppm/oC
Defined at the operating temperature range 0 to 50oC.
Resistance thermometer
Code |
Temperature Sensor |
Measuring Range |
Display Range |
3 |
Pt100Ω (JIS’97) |
-200 to 850°C |
-200 to 870°C |
JPt100Ω (JIS’81) |
-200 to 649°C |
-200 to 660°C |
Pt50Ω (JIS’81) |
-200 to 649°C |
-200 to 660°C |
Ni508.4Ω |
-200 to 280°C |
-50 to 300°C |
-
Accuracy:
-
±(0.1% of FS + 1 digit)
Defined at 23oC±5oC, in the measuring range.
Calibration is with the values of each referential resistor element of JIS C-1604-1997.
-
Temperature coefficient :
-
±150 ppm/oC
Defined at the operating temperature range 0 to 50oC.
② Output Signal
Code |
Specifications |
1 |
Two relay contact output |
2 |
Four relay contact output |
3 |
Two open collector output |
4 |
Four open collector output |
③ Power Supply Voltage
Code |
Power Supply Voltage |
A |
AC 100 to 240 V |
B |
DC 12 to 24 V |
C |
DC 110 V |
Specifications/Model
Specification / Model |
2512 |
2522 |
2532 |
|
|
|
|
Dimension (W x H x D mm) excl .Base socket |
28.5 × 72 × 115 |
Input |
DC current / voltage |
● |
- |
- |
Process |
● |
- |
- |
T/C (R,K,E,J,T,B,N,S,WRe5-26) |
- |
● |
- |
RTD (Pt100Ω,JPt100Ω,Pt50Ω,Ni508.4Ω) |
- |
- |
● |
Output |
Nos. of Alarm |
2points |
● |
● |
● |
4points |
● |
● |
● |
Accuracy |
Repeatability |
±(0.1% of FS + 1digit) |
Output |
Relay |
● |
● |
● |
Open collector |
● |
● |
● |
Setting style |
Key |
● |
● |
● |
Alarm type (H/L) |
H or L adjustable |
● |
● |
● |
Comparator ON/OFF Switchable |
● |
● |
● |
Rating |
Relay |
250 V, 1 A a.c., 30 V, 2 A d.c. |
Open collector |
50 V, 100 mA d.c. |
Response |
Less than 150ms |
Less than 400ms |
Less than 1.2s |
Display |
4 digit ( -9999 to 9999) |
● |
● |
● |
Zero suppress |
● |
● |
● |
Scaling |
● |
- |
- |
Off display |
● |
● |
● |
Offset |
● |
- |
- |
Status |
● |
● |
● |
Function |
Hysteresis |
● |
● |
● |
Output delay |
● |
● |
● |
Power on delay |
● |
● |
● |
Deviation setting |
● |
● |
● |
Test mode |
● |
● |
● |
Moving average |
● |
● |
● |
Operating temperature |
0-50°C |
Operating humidity |
30 - 90% RH (no condensation) |
AC power supply |
100 to 240 V a.c. |
DC power supply |
12 to 24 V d.c., 110 V d.c. |
Weight |
approx. 180 g |
●:Standard, ○:Option