Product Range:
R32 Inverter Single Split
R32 Inverter Single Split
Capacities:
2.0 – 6.0 hp
2.0 – 6.0 hp
Refrigerant:
R32
R32
Technical Spefications
FCF-C Series
|
||||||
---|---|---|---|---|---|---|
Indoor | FCF50CVM | FCF60CVM | FCF71CVM | FCF100CVM | FCF125CVM | FCF140CVM |
Outdoor | RZF50CVM | RZF60CVM | RZF71CVM | RZF100CVM | RZF125CVM | RZF140CVM |
Specifications / Model name | ||||||
Type | Inverter | |||||
Horsepower (hp) | 2.0 | 2.5 | 3.0 | 4.0 | 5.0 | 6.0 |
Refrigerant | R32 | |||||
Rated Cooling Capacity (Btu/h) (Min-Max) | 17,100 (10,900-19,100) | 20,500 (10,900-20,500) | 24,200 (10,900-27,300) | 34,100 (17,100-38,200) | 42,700 (19,500-47,800) | 47,800 (21,200-52,900) |
Rated Power Consumption (W) | 1,140 | 1,530 | 1,930 | 2,970 | 4,180 | 5,470 |
COP (W/W) | 4.39 | 3.92 | 3.68 | 3.37 | 2.99 | 2.56 |
CSPF (Wh/Wh) | 6.60 | 6.31 | 6.17 | 5.50 | 5.15 | 5.00 |
Air Flow Rate (H/HM/M/ML/L)-CFM | 812/ 741/ 653/ 565/ 477 | 1,218/ 1,094/ 971/ 847/ 706 | 1,288/ 1,165/ 1,024/ 883/ 741 | |||
Power Source (V/Ph/Hz) | 220-240/ 1/ 50 | |||||
Sound Pressure Level - Indoor (H/HM/M/ML/L) (dBA) | 37.0/ 34.5/ 32.0/ 29.5/ 27.5 | 45.0/ 41.5/ 38.0/ 35.0/ 32.5 | 46.0/ 43.0/ 40.0/ 36.0/ 32.5 | |||
Dimension - Indoor (H x W x D) mm | 256 x 840 x 840 | 298 x 840 x 840 | ||||
Dimension - Outdoor (H x W x D) mm | 595 x 845 x 300 | 695 x 930 x 350 | 990 x 940 x 320 | |||
Unit weight - Indoor (kg) | 22 | 24 | ||||
Unit weight - Outdoor (kg) | 41 | 48 | 64 | |||
Copper Pipe Size - Liquid (mm) | 9.52 | |||||
Copper Pipe Size - Gas (mm) | 15.88 | |||||
Controller | Wired/ Wireless |