您已经添加该商品到您的收藏列表
从您收藏列表中删除此商品。
这家公司已成功添加。 查看我的收藏.
这家公司已从你的收藏夹列表中删除。
这家公司已被添加到您的询问车。
这家公司已从询价车中删除。
该商品已被添加到您的询问车。
该商品已经从您的询价车中删除。
商品/公司已达到添加至询价车的数量。
登入NEWPAGES
保持登入状态
每日登录奖励

恭喜! 你获得了今天的每日登录奖励!

5 NP Point这是您获得的奖励!
查看您的每日登录奖励

确保每天回来登入以获更多的奖励!
谢谢!

Back
Seni Jaya Logo
XTS Technologies Sdn Bhd
XTS Technologies Sdn Bhd (879680-H)
访客

Heat Conduction / Heat Dissipation

21-Jan-2020
Heat Conduction / Heat Dissipation
标签:
-
产品已浏览 72
Thermal is always a concern especially for heavy loading equipment that will generated massive heat, environment with thermal issue will impact overall performance or even result in system shut down. Rear door heat exchanger provide excellence cooling performance that helps solving common thermal issues in data center. Kenmec thermal solution for datacenter can be divided into two parts: Rear door heat exchanger and cooling distribution unit (CDU).

A. CDU: Chilled water for primary loop that can be supply either from tap water, chiller or existing cooling facilities, this chilled water will flow to plate heat exchanger and performance heat exchange with secondary loop; secondary loop on CDU supply cooling liquid that above dew point to ensure no condensation problem, these cooling liquid will flow through heat source and return to plate heat exchanger.
B. Rear door heat exchanger: Depends on thermal requirement, rear door heat exchanger available in 20KW and 30KW that meet specification of standard cabinet and load capacity on the market. Mainly used in data center, it is an energy-saving thermal solution that helps reduce the PUE below 1.4.

(1) Main structure of CDU
1. AC motor: Maximum working pressure 50psi, maximum flow 360LPM. (LX360)
2. Cooling water impurity filter.
3. Water supply / return line distribution connector.
4. High efficiency plate heat exchanger.
5. Intelligent setting and monitoring panel.
6. Abnormal condition alarm system.

(2) Principle of Action
System fan force cold air into cabinet and bring hot air toward rear door for heat exchange, these exchanged heat will then send to external cooling system (chiller) by chilled water in rear door, thus air temperature after passing through rear door will equal to or less than room temperature.
发信息至 XTS Technologies Sdn Bhd

谢谢您的询问!
我们的客服会尽快联络您。

如需咨询或问题,联系我们
总办事处

XTS Technologies Sdn Bhd (879680-H)
21, Jalan MJ14, Taman Industri Meranti Jaya, 47120 Puchong, Selangor, Malaysia.
Google Maps Waze

电话: +6012-522 8019, +603-8066 2496
传真: +603-8066 2496

邮件: sales@xtstech.com
网址: https://www.logisticsolutions.com.my
网址: https://www.xteven.com
网址: https://logisticsolutions.newpages.com.my/
网址: http://logisticsolutions.n.my/

其他办事处

Johor Office
18, Jalan Austin Perdana 2/22, Taman Austin Perdana, 81100 Johor Bahru, Johor, Malaysia.
Google Maps Waze

社交媒体链接
  • blogger