GENLINK™ DPNL

12-Jun-2018
GENLINK™ DPNL
标签:
-
产品已浏览 207

Dissimilar Pitch Neutral Limiter

GENLINK DPNL is a multiple winding reactor that, when installed in the common neutral of paralleled sources either between the dissimilar generators or the generator and the utility supply, can greatly reduce the neutral circulating currents that result from the instantaneous voltage differences. These neutral circulating currents, which are predominantly triple frequency, have the potential to cause a considerable amount of damage with respect to overheating generators and causing false-protection trips.

Voltage differences in paralleled generators made by different manufacturers or differences in standard pitch design configurations in generators made by the same manufacturer can result in heavy neutral circulating currents. Additionally, alternative energy sources such as solar and wind power that generate AC power can introduce heavy circulating currents in 4-wire parallel applications. When applied, GENLINK will impede the flow of circulating currents while adding only minimal impedance to the fault current path.

GENLINK DPNL can be used in both 3-wire and 4-wire systems. For 4-wire applications where there is return neutral current from 1-Ph loads, the DPNL must be sized for this current as well as the circulating current. For 3-wire applications where there is no return neutral current from 1-Ph loads, a smaller size DPNL can be used. Grounding of the neutral must be done at only one location, which is recommended to be the distribution switchboard.

Features

  • Inserts >40% impedance in neutral current circulating path
  • Reduces neutral circulating current by >75%
  • Adds <1% saturated impedance to 1-Ph fault path
  • No impedance to 3-Ph fault path
  • Use in 3-wire or 4-wire applications or any parallel source application with a common neutral and dissimilar voltage waveforms
  • Eliminates generator overheating and false protection trips caused by triple frequency circulating currents
  • Easy to install
  • Reliable and proven performance
发信息至 UTC Engineering Sdn Bhd

谢谢您的询问!
我们的客服会尽快联络您。

获取最新的 UTC Engineering Sdn Bhd 应用程序 iOSAndroid
如需咨询或问题,联系我们
总办事处

UTC Engineering Sdn Bhd (805959-D)
3 & 5, Jalan USJ 21/11, UEP Subang Jaya, 47630 Selangor, Malaysia.
Google Maps Waze

电话: +603-8023 6708
传真: +603-8023 6709

邮件: yewtc@ee.com.my
网址: http://www.utcesb.com.my
网址: https://utcesb.newpages.com.my/
网址: http://utcesb.n.my/

Powered by NEWPAGES