Pelawat

Thermostatic expansion valves Type TE 5 – TE 55

03-Apr-2020
Thermostatic expansion valves Type TE 5 – TE 55
Tags:
-
Produk Dilihat 139
   
Thermostatic Expansion Valves, Type TE5 - TE 55
           
                 
Thermostatic element - including bulb strap
             

R22

Valve
type
Pressure
equalization
Capillary
tube
Code no.
Range N
-40°C to +10°C
Range NM
-40 to -5°C
Range NL
-40 to -15°C
Range B
-60 to -25°C
¼ in. / 6mm m Without MOP MOP+15°C MOP 0°C MOP 0°C Without MOP MOP -20°C
TEX 5 Ext. 1) 3 067B3250 067B3267 067B3253 067B3253 067B3263 067B3251
TEX 12 Ext. 3 067B3210 067B3227 067B3207 067B3213   067B3211
TEX 12 Ext. 5 067B3209         067B3212
TEX 20 Ext. 3 067B3274 067B3286 067B3273 067B3275   067B3276
TEX 20 Ext. 5 067B3290         067B3287
TEX 55 Ext. 3 067G3205 067G3220 067G3206     067G3207
TEX 55 Ext. 5 067G3209         067G3217
1) Pressure equalization, please contact Danfoss.
             

Orifice assembly
         
Valve type
Rated capacity
Range N:
-40°C to 10°C
kW
Rated capacity kW
Range B:
-60°C to -25°C
kW
Orifice no.
Code no.
 
 
 
TEX 5-3 11,1 6,4 0.5 067B2788  
TEX 5-5.5 18,8 11 1 067B2789  
TEX 5-7.5 26,1 15,8 2 067B2790  
TEX 5-10 33,9 19,5 3 067B2791  
TEX 5-13 44,8 25,9 4 067B4792  
TEX 12-17 60 35,6 5 067B2708  
TEX 12-21 72,7 42 6 067B2709  
TEX 12-24 84,5 46,4 7 067B2710  
TEX 20-32.5 131,6 55,0 8 067B2771  
TEX 20-37.5 131,5 57,5 9 067B2773  
TEX 55-44.5 156,3 68,2 10 067G2701  
TEX 55-54 190,0 77,8 11 067G2704  
TEX 55-65.5 228,8 95,3 12 067G2707  
TEX 55-80 281,0 131,4 13 067G2710  
The rated capacity is based on:
         
Evaporating temperature
   
t = +4°C for range N and t = -30°C for range B
   
Condensing temperature
    t = +38°C    
Refrigerant temperature ahead of valve
    t = +37°C  


Valve body            
Type
Connection
Inlet x Outlet
Code no.
in.
mm
flare
angleway
Solder
angleway
Solder
straightway
Solder
flanges
TE 5
 
 
067B4013
067B4009
067B4010
067B4011
067B4034
067B4007
067B4008
067B4032
067B4033
 
TE 5
 
12 x 16
12 x 22
16 x 22
22 x 28
067B4013
067B4004
067B4005
067B4012
067B4037
067B4002
067B4003
067B4035
067B4036
 
TE 12
 
 
 
067B4023
067B4021
 
TE 12
 
16 x 22
22 x 25
22 x 28
 
067B4017
067B4016
067B4025
067B4026
TE 20
 
22 x 28
 
067B4023
067B4017
067B4021
067B4016
067B4027
067B4015
TE 55
 
28 x 35
 
067B4004
067B4002
067B4003
067B4001
 
             
1) ODF x ODF            
2) OD x ODM            
3) ODM x ODM            
ODF = Internal diameter
           
ODM = External diameter
         

Thermostatic element - including bulb strap
             
R404A/R507
Valve
type
Pressure
equalization
Capillary
tube
Code no.
Range N
-40°C to +10°C
Range NM
-40 to -5°C
Range NL
-40 to -15°C
Range B
-60 to -25°C
¼ in. / 6mm m Without MOP MOP+15°C MOP 0°C MOP 0°C Without MOP MOP -20°C
TES 5 Ext. 1) 3 067B3342   067B3357 067B3358 067B3344 067B3343
TES 12 Ext. 3 067B3347   067B3345 067B3348   067B3349
TES 12 Ext. 5 067B3346         067B3350
TES 20 Ext. 3 067B3352   067B3351 067B3353   067B3354
TES 20 Ext. 5 067B3356         067B3355
TES 55 Ext. 3 067G3302   067G3303 067G3304   067B3305
TES 55 Ext. 5 067G3301         067G3306
1) Pressure equalization, please contact Danfoss.
               
               

Orifice assembly
         
Valve type
Rated capacity
Range N:
-40°C to 10°C
kW
Rated capacity kW
Range B:
-60°C to -25°C
kW
Orifice no.
Code no.
 
 
 
TES 5-2.5 8,7 5,7 0.5 067B2788  
TES 5-4.0 14,6 9,9 1 067B2789  
TES 5-6 20,1 14,4 2 067B2790  
TES 5-7.5 26,3 17,3 3 067B2791  
TES 5-10 34,6 22,9 4 067B2792  
TES 12-14.5 50,6 24,2 5 067B2708  
TES 12-17.5 61,0 28,4 6 067B2709  
TES 12-20 70,6 31,0 7 067B2710  
TES 20-22 77,6 43,8 8 067B2771  
TES 20-24 84,5 44,0 9 067B2773  
TES 55-34 118,4 52,3 10 067G2701  
TES 55-41 143,2 58,9 11 067G2704  
TES 55-48.5 170,3 71,0 12 067G2707  
TES 55-60 209,8 100,2 13 067G2710  
           
The rated capacity is based on:
         
Evaporating temperature
   
t = +4°C for range N and t = -30°C for range B
   
Condensing temperature
    t = +38°C    
Refrigerant temperature ahead of valve
    t = +37°C    
         

Hantar mesej anda ke A T C Marketing Sdn Bhd

Terima kasih untuk pertanyaan anda!
Perkhidmatan pelanggan kami akan menghubungi anda tidak lama lagi.

Send us your inquiry or question
Pejabat Utama

A T C Marketing Sdn Bhd (353173-A)
17, Jalan 7/152, Taman Perindustrian OUG, Batu 6, Jalan Puchong, 58200 Kuala Lumpur, Malaysia.
Google Maps Waze

Tel: +603-7781 3276, +603-7781 3284
Fax: +603-7781 4509

Emel: atc_mkt@yahoo.com
Laman Web: https://www.atcmarketing.com.my
Laman Web: https://atcmarketing.newpages.com.my/
Laman Web: http://atcmarketing.n.my/

601162755201
+601162755201
Media Sosial Link
  • facebook

Powered by NEWPAGES