You have added this product to your favorite list.
You have removed this product from your favourite list.
This company has been added successfully. Check My Favourite.
This company has been removed from your favourite list.
This company has been added to your inquiry cart.
This company has been removed from your inquiry cart.
This product has been added to your inquiry cart.
This product has been removed from your inquiry cart.
Maximum number of Product/Company has been reached in inquiry cart.
Login to NEWPAGES
Stay signed in
Daily Login Reward

Congratulations! You’ve earned your daily login reward for today!

5 NP PointHere are the reward you’ve earned!
Check your Daily Login Rewards

Be sure to come back everyday for more rewards!
Thanks!

Back
Pelawat

GENLINK™ DPNL

12-Jun-2018
GENLINK™ DPNL
Tags:
-
Produk Dilihat 39

Dissimilar Pitch Neutral Limiter

GENLINK DPNL is a multiple winding reactor that, when installed in the common neutral of paralleled sources either between the dissimilar generators or the generator and the utility supply, can greatly reduce the neutral circulating currents that result from the instantaneous voltage differences. These neutral circulating currents, which are predominantly triple frequency, have the potential to cause a considerable amount of damage with respect to overheating generators and causing false-protection trips.

Voltage differences in paralleled generators made by different manufacturers or differences in standard pitch design configurations in generators made by the same manufacturer can result in heavy neutral circulating currents. Additionally, alternative energy sources such as solar and wind power that generate AC power can introduce heavy circulating currents in 4-wire parallel applications. When applied, GENLINK will impede the flow of circulating currents while adding only minimal impedance to the fault current path.

GENLINK DPNL can be used in both 3-wire and 4-wire systems. For 4-wire applications where there is return neutral current from 1-Ph loads, the DPNL must be sized for this current as well as the circulating current. For 3-wire applications where there is no return neutral current from 1-Ph loads, a smaller size DPNL can be used. Grounding of the neutral must be done at only one location, which is recommended to be the distribution switchboard.

Features

  • Inserts >40% impedance in neutral current circulating path
  • Reduces neutral circulating current by >75%
  • Adds <1% saturated impedance to 1-Ph fault path
  • No impedance to 3-Ph fault path
  • Use in 3-wire or 4-wire applications or any parallel source application with a common neutral and dissimilar voltage waveforms
  • Eliminates generator overheating and false protection trips caused by triple frequency circulating currents
  • Easy to install
  • Reliable and proven performance
Hantar mesej anda ke UTC Engineering Sdn Bhd

Terima kasih untuk pertanyaan anda!
Perkhidmatan pelanggan kami akan menghubungi anda tidak lama lagi.

Get the latest UTC Engineering Sdn Bhd App for iOS and Android
Send us your inquiry or question
Pejabat Utama

UTC Engineering Sdn Bhd (805959-D)
3 & 5, Jalan USJ 21/11, UEP Subang Jaya, 47630 Selangor, Malaysia.
Google Maps Waze

Tel: +603-80136708
Fax: +603-80236709

Emel: yewtc@ee.com.my
Laman Web: http://www.utcesb.com.my
Laman Web: https://utcesb.newpages.com.my/
Laman Web: http://utcesb.n.my/

Powered by NEWPAGES